This page contains technical information and specifications of our treatment solutions devices, and is intended solely for healthcare professionals.
To ensure that the content you receive is tailored to your region, please select your location from the available options. By doing so, we will be able to provide you with information pertaining to products and services that are specific to your region. This will enable us to better meet your needs and ensure that you receive the best experience possible.
Purpose: During follow-up of patients treated with WEB devices, shape changes have been observed. The quantitative three-dimensional measurement of the WEB shape modification (WSM) would offer useful information to be studied in association with the anatomical results and try to better understand mechanisms implicated in this modification phenomenon.
Flow diverters are widely extended in clinical practice for intracraneal aneurysms treatment. They are formed by a dense mesh of braided wires that partially occludes the aneurysm neck and restores the blood flow into the parent vessel. The occlusion degree is highly dependant on the distribution of the wires under the aneurysm, which is affected by the vessel geometry. Nowadays, there are no clinical indicators of the covering ratio once the flow diverter is deployed.
Intra-saccular devices (ID) are novel braided devices used for complex intracranial aneurysms treatment. Treatment success is associated with correct device size selection. A technique that predicts the ID size within the aneurysm before intervention will provide a powerful computational tool to aid the interventionist during device selection.
Flow-Diverter (FD) porosity has been pointed as a critical factor in the occlusion of cerebral aneurysms after treatment. Objective: Verification and Validation of computational models in terms of predictive capacity, relating FD porosity and occlusion after cerebral aneurysms treatment.
Intra-saccular devices (ID), developed for the treatment of bifurcation aneurysms, offer new alternatives for treating complex terminal and bifurcation aneurysms. In this work, a complete workflow going from medical images to post-treatment CFD analysis is described and used in the assessment of a concrete clinical problem.
Sizing of flow diverters (FDs) stent in the treatment of intracranial aneurysms is a challenging task due to the change of stent length after implantation
Flow diverter (FD) devices show severe shortening during deployment in dependency of the vessel geometry. Valid information regarding the geometry of the targeted vessel is therefore mandatory for correct device selection, and to avoid complications. But the geometry of diseased tortuous intracranial vessels cannot be measured accurately with standard methods. The goal of this study is to prove the accuracy of a novel virtual stenting method in prediction of the behavior of a FD in an individual vessel geometry.
Intrasaccular devices, like Woven EndoBridge (WEB), are novel braided devices employed for the treatment of aneurysms with a complex shape and location, mostly terminal aneurysms. Such aneurysms are often challenging or impossible to treat with other endovascular techniques such as coils, stents, flow diverter stents.
Flow diverters are widely extended in clinical practice for intracraneal aneurysms treatment. They are formed by a dense mesh of braided wires that partially occludes the aneurysm neck and restores the blood flow into the parent vessel. The occlusion degree is highly dependant on the distribution of the wires under the aneurysm, which is affected by the vessel geometry. Nowadays, there are no clinical indicators of the covering ratio once the flow diverter is deployed. We propose a novel method for the simulation of the flow diverter local porosity before its deployment into the parent vessel. We validate the method on curved silicon models, obtaining a correlation of 0.9 between the simulated values and the measured porosity on the deployed flow diverter.
We are here to guide and help you find the solution that is the best fit for your unique needs. Fill in the form to connect with us and a suitable solution expert will get back to you as soon as possible
Rambla Catalunya 53, 4-H, 08007, Barcelona, Spain.
+34 933 28 39 64
Disclaimer & Regulatory Information
Ankyras is manufactured by Mentice Spain S.L. and distributed by Mentice subsidiaries and partners in approved markets.
Mentice Spain SL: Mentice Spain SL has obtained the ISO 13485 certification with number MD 784027
Ankyras certifications: The Ankyras product complies with the Medical Device Regulation (EU CE Mark, MDR 784032) and the UK Conformity Assessed (UKCA 784033)